Protect escape
Follow routes from occupied areas to a usable final exit and safe destination.
Practical checklist
CURRENTUse this fire safety checklist to review visible escape, detection, first-response equipment, ignition control, combustible storage, hot work and emergency readiness. It supports a workplace walk-through but does not replace a fire-risk assessment, system test, maintenance visit or approval by a competent specialist.

Follow routes from occupied areas to a usable final exit and safe destination.
Look at storage, hot work, charging, temporary electrics and process changes together.
Visible equipment, current records and people who know what to do all matter.
Begin where people work and follow the full escape path. A clear door is not enough if the corridor, stair, final exit or external route is blocked or locked.
A visual inspection can reveal obstruction, damage or missing information, but it does not prove that an alarm, detector, suppression system or extinguisher will perform. Use current specialist test and maintenance records where required.
Adapt these field prompts to the building, occupancy, process, fire strategy and applicable requirements.
Are routes continuous, adequately lit, clearly recognizable and free from storage, locked barriers and dangerous level changes?
Can final exits be opened as intended, and is the external route to safety unobstructed?
Are fire doors closed or held only by approved means, undamaged and free from wedges or penetrations that defeat separation?
Are escape and equipment signs visible, and are test or defect records available for required emergency lighting?
Are alarm points, detectors and sounders unobstructed and free from obvious damage, with impairments clearly managed?
Are extinguishers or hose systems accessible, identified, visibly serviceable and appropriate to the site plan?
Are waste, packaging and other combustibles controlled and separated from ignition, escape routes and critical equipment?
Are flammable liquids or gases identified, closed, quantity-controlled and stored or used in the designated conditions?
Is hot work authorized, the area prepared, combustible exposure controlled and post-work fire watch implemented?
Are temporary supplies, overloaded sockets, damaged equipment, batteries and charging areas free from obvious heat or fire risk?
Are fire-service access, hydrants, panels, isolation points and essential information reachable and identified?
Are roles, contacts, assembly arrangements, assistance needs and recent changes communicated and practiced as required?
No. A visual field check and specialist inspection or maintenance serve different purposes.
Control the exposure promptly under the site's emergency arrangements and record permanent follow-up if more work is needed.
Escalate under the building's fire plan, apply authorized temporary controls and verify restoration with competent support.
Yes. Findings, evidence, due dates and verification can be retained in the local inspection workflow.
Trace the route people would use, distinguish visual condition from tested performance and verify every restored control before closure.
Use this checklist in FenwixContent status: CURRENT · Last reviewed: 2026-08-16
Claim basis: Fenwix independently authored field checklist content · Fenwix current application flow · Fenwix editorial accuracy standard